THYRO A, Регулятор мощности Thyro Advanced Energy тиристорного типа
RadiusVip.ru

Источники бесперебойного питания (UPS/ИБП):
AEG Power Solutions, Eaton (Powerware), Liebert (Vertiv), Riello
Системы прецизионного кондиционироввания воздуха:
RC Group, Munters, Montair, Clint

RadiusVip.Ru

101000, Москва, Колпачный переулок, д. 6 стр. 2

Тел.: (495) 6-410-410

E-mail: welcome@rvip.ru

Написать письмо
>>>

Главная страница  |  Регуляторы мощности  |  Thyro-A

Thyro-A

Thyristor Power Controller (SCR) up to 1,500 A

Advanced Energy THYRO A
Safe, fast, economical and communication enabled

Owing to high-capacity digital technology, the new communication enabled Thyristor Power Controller Thyro-A allows for precise energy dosing at a high level of availability.

Heating — Melting — Forming

Highly flexible for interfacing the load and power supply side, the range of applications for Thyro-A has expanded signifi — cantly. For  standard processes, adjustments can be made on the unit, which facilitate handling and speed up commissioning.

Owing to an interface option at the automation level, many  further functions can also be used. All measurement, status, and set points may  be processed via SPS or the process computer. Of course, stand-alone operations or the direct combination with process controls are still possible.

Thyro-A power controllers are thus excellently suited for  application in numerous fields within the scope of process engineering technology, for example:

  • Ovens (industrial, diffusion, drying)
  • Glass processing (plate glass equipment, feeders, finishing equipment, fiber glass)
  • Plant equipment (extruders, plastic presses)
  • Chemical industry (pipe trace heaters, pre-heating equipment),
  • Automotive industry (paint drying equipment),
  • Printing machines (IR drying),
  • Packaging industry (shrink tunnels)

Брошюра Thyro-AБрошюра Thyro-A

Листовка Thyro-AЛистовка Thyro-A

Инструкция по эксплуатации Thyro-AИнструкция по эксплуатации Thyro-A

SpecificationSpecification

Key Features

Besides free-from-wear operations and high performance, this product series offers the following features:

  • Simple handling requiring little space
  • Rated voltages up to 600 V
  • Rated currents up to 1,500 A
  • Single, dual, and three-phase versions (Dual-phase version for three-phase load without deploying the neutral conductor in a cost-saving three-phase circuit)
  • Integrated semi-conductor fuses
  • LED status indicators
Automation Level
  • Series-design system interface for connection to an optional bus module (Profi bus DPV1, Modbus RTU, DeviceNet, CANopen, Profi Net. Projected: ModBus TCP/IP, Ethernet IP) for the processing of set points and actual values, as well as for status reports
  • Interface option for connection to PC software Thyro-Tool Family
  • Safe separation of control and power units
Analog Controlling
  • Analog set point between 0..10V / 0..20mA
  • Control characteristic is adjustable within this interval
  • Voltage range at the dual point controller: OFF=0..3V, ON=3..24V
Load Side
  • High resistance against short-circuit currents and blocking voltage accommodated by the power semiconductors
  • Designed for ohmic load, as well as for inductive mixed load
  • Fit for transformer-type load due to an integrated soft-start function, phase-angle firing of the first half-wave and channel separation
  • Optimized load control due to the implementation of up to 5 control types and 3 operating modes
Power Supply Side
  • Network voltages of up to 0.43 x Unom
  • Frequency range 47-63 Hz
  • Internal network load optimization in the operating modes TAKT and QTM
  • Optional external network load optimization (Thyro-Power Manager Module)
Other Features
  • Quality standard met in accordance with ISO 9001
  • Approval in accordance with UL 508
  • S.C.C.R. certified in accordance with UL 508A (100 kA short-circuit test, accredited 16 A to 350 A, projected 495 A to 1,500 A)
  • Canadian National Standard
  • CE Conformity
  • GOST
  • RoHS Conformity 5/6

Наверх

SpecificationSpecification

Thyro-Power Manager

Thyro-Tool Family

Наверх

Specification – type series and technical data (excerpt)Specification – type series and technical data (excerpt)

Operating Modes

TAKT, full frequency package control

frequency package control

 

VAR, phase-angle

firing of each sinus half-wave

 

QTM, half-wave frequency package control

quick operating mode for ohmic load without a transformer

Thyro-A

1A...

single-phase version, for single-phase load between dual phases, or for a single phase connected to the neutral phase

 

 

Operating modes:

TAKT, VAR, QTM

 

2A...

dual-phase version for three-phase load in cost-saving three-phase circuit

 

 

Operating mode:

TAKT

 

3A...

three-phase version, for three-phase load

 

 

Operating modes:

TAKT, VAR

Rated Voltage ...H1

...230... 230 V - 57 % + 10 %

 

...400... 400 V - 57 % + 10 %

 

...500... 500 V - 57 % + 10 %

Rated Voltage ...H RL1 and H RLP1

...230... 230 V - 15 % + 10 %

230 V - 57 % together with 24 V input

 

...400... 400 V - 15 % + 10 %

400 V - 57 % together with 24 V input

 

...500... 500 V - 15 % + 10 %

500 V - 57 % together with 24 V input

 

...600... 600 V - 15 % + 10 %

600 V - 57 % together with 24 V input

 

Network frequency

of all types ranging from 47 Hz to 63 Hz
Max. frequency change 5 % per half-wave

Rated Current

...-xxx...

16 A, 30 A, 45 A, 60 A, 100 A, 130 A, 170 A, 280 A, 350 A, 495 A, 650 A, 1.000 A, 1.400 A, 1.500 A

 

Load Type

Load types for ohmic load employed at a Rwarm/Rcold ratio of up to 6; Transformerload

 

Network load

optimization via internal network load optimization for the operating modes QTM and TAKT
Interface for external network load optimization available, e.g. Thyro-Power Manager

Functional Features

...F...

forced ventilation

 

 

Setpoint inputs

2 setpoint inputs, separated safely (SELV, PELV) from the mains

 

 

 

Input of analog setpoint, signal intervals:

 

 

 

0(4) - 20 mA / 0(1) - 5 V / 0(2) - 10 V

 

 

 

Control input for switch operation mode – dual-point control is possible (UOn = 3-24 V)

 

 

 

The digital setpoint is provided by the process computer or bus system

 

...H 1

control types

Ueff, U2eff

 

...H RL1

functional features

such as ...H 1, yet additionally

 

 

Control types

Ueff, U2eff, Ieff, I2eff

 

 

Load monitoring

via an adjustable response threshold

 

 

Limitations

current limitation Ieff, Î in VAR mode, current peak limitation to Î = 3 x Inom

 

 

Relay output

exchanger, max. contact load 250 V, 6 A, 180 W, 1500 VA

 

 

Analog output

signal level 0(2)-10 Volt / 0(4)-20 mA, maximum compliance voltage 10 V, can also be used as adjustment aid

 

 

external supply

24 V DC/AC, connected only upon demand

 

 

Load types

for ohmic load employed at a Rwarm/Rcold ratio of up to 6 (only deployed for H RL1 and H RLP)

 

 

 

Limitation to Î = 3 x Inom (for H RL1 and H RLP in VAR mode)

 

 

Operational display

via LEDs and relay outputs (exchanger, indications adjustable)

 

...H RLP1

functional features

such as ... H RL1, however, additionally

 

 

control types

Ueff, U2eff, Ieff, I2eff, P

System interface

Optional bus module for Profibus DPV1, Modbus RTU, DeviceNet, CANopen, ProfiNet.
Projected: ModBus TCP/IP, Ethernet IP.

 

For interfacing the PC software of the Thyro-Tool Family via a PC adaptor

Examples regarding the type key

Thyro-A 2A 400-170 HRLP1

 

2A = dual phase version for three phase load in cost-saving three-phase circuit, 400 = 400 V rated voltage

 

170 = 170 A rated current, H = semi-conductor fuse, R = failure indicator relay

 

L = load monitoring + analog output, P = performance control display, 1 = actual series

Наверх

Specification - type series and technical data (excerpt)Specification - type series and technical data (excerpt)

THYRO-A 1A
H1(*), HRL1, HRLP1

Single-phase power controller

 

Current

Unit rating (kVA)

Power loss

Dimensions (mm)

Weight (kg)

THYRO-A 1A

…H1 …HRL1 …HRLP1

(A)

230 V

400 V

500 V

600 V

(W)

W

H

D

approx.

 

16

3.7

6.4

8

30

45

131

127

0.7

 

30

6.9

12

15

47

45

131

127

0.7

 

45

10

18

22.5

48

52

190

182

1.7

 

60

14

24

30

80

52

190

182

1.7

 

100

23

40

50

105

75

190

190

1.9

 

130

30

52

65

150

125

320

237

4

 

170

39

68

85

210

125

320

237

4

..F..

280

64

112

140

330

125

370

237

5

..F..

350

80

140

175

390

125

400

261

8.4

..F..

495

198

274

297

556

112

414

345

15

..F..

650

260

325

390

638

112

414

345

15

..F..

1000

400

500

600

1277

239

729

516

35

..F..

1400

750

900

1700

239

729

516

35

..F..

1500

600

1703

239

729

516

35

THYRO-A 2A
H1(*), HRL1, HRLP1

Dual-phase power controller for three-phase loads implement with cost-saving three-phase circuit configuration

 

Current

Unit rating (kVA)

Power loss

Dimensions (mm)

Weight (kg)

THYRO-A 2A

…H1 …HRL1 …HRLP1

(A)

230 V

400 V

500 V

600 V

(W)

W

H

D

approx.

 

16

11

14

60

90

131

127

1.4

 

30

21

26

94

90

131

127

1.4

 

45

31

39

96

104

190

182

3.4

 

60

42

52

160

104

190

182

3.4

 

100

69

87

210

150

190

190

3.8

 

130

90

112

300

250

320

237

8

 

170

118

147

420

250

320

237

8

..F..

280

194

242

660

250

393

237

11

..F..

350

242

303

780

250

430

261

16.7

..F..

495

343

429

514

1190

194

380

345

22

..F..

650

450

563

675

1465

194

380

345

22

..F..

1000

693

866

1039

2785

417

685

516

54

..F..

1400

1299

1599

3300

417

685

516

54

..F..

1500

1039

3510

417

685

516

54

THYRO-A 3A
H1(*), HRL1, HRLP1

Three-phase power controller

 

Current

Unit rating (kVA)

Power loss

Dimensions (mm)

Weight (kg)

THYRO-A 2A
(*) …H1 types available up to 350 A

…H1 …HRL1 …HRLP1

(A)

230 V

400 V

500 V

600 V

(W)

W

H

D

approx.

 

16

11

14

90

135

132

127

2.1

 

30

21

26

141

135

132

127

2.1

 

45

31

39

144

156

190

182

5.1

 

60

42

52

240

156

190

182

5.1

 

100

69

87

315

225

190

190

5.7

 

130

90

112

450

375

320

241

12

 

170

118

147

630

375

320

241

12

..F..

280

194

242

990

375

397

241

15

..F..

350

242

303

1170

375

430

261

25.5

..F..

495

343

429

514

1860

276

407

345

30

..F..

650

450

563

675

2265

276

407

345

30

..F..

1000

693

866

1039

4310

583

685

516

74

..F..

1400

1299

1559

5000

583

685

516

74

..F..

1500

1039

5325

583

685

516

74

Наверх

+7 (495) 6-410-410

welcome@rvip.ru